Wet 60m² Underfloor Heating Kit

Experience premium heating comfort with our efficient Wet Underfloor Heating Kit, suitable for up to 60 sq/m. This kit is designed for easy integration with your existing boiler, making installations straightforward for different environments including residential or commercial space. Explore more in our water underfloor heating range.

This exclusive kit includes:

  • Settings for 45.0 m² at 150mm spacing in high-loss areas 
  • 60.0 m² at 200mm spacing for primary heating
  • 90.0 m² at 300mm spacing for secondary heating zones
Incl. Vat: £504.00 £420.00
Availability: In stock
SKU
UFH242

60m² Multi-Zone Wet Underfloor Heating Kit

Planning water underfloor heating for an extension and adjoining living spaces? The 60m² multi-zone wet underfloor heating kit is intended for a traditional screeded floor, with heating pipe clipped securely to suitable insulation before an appropriate screed is laid. It brings together principal components for designing a comfortable, water-based heating system without having to source each item separately.

Well suited to correctly designed new-builds, extensions and major renovations, this kit lets an installer divide the heated area into suitable pipe circuits connected to a manifold. Warmth is delivered through the floor rather than wall-mounted radiators, making it easier to plan flexible room layouts.

Why choose this 60m² multi-zone underfloor heating kit?

  • Project-sized system: designed around approximately 60m² at the specified pipe spacing and heat-loss requirements.
  • Traditional screed installation: pipes are clipped to suitable insulation and embedded in screed, not laid in retrofit overlay boards.
  • Multi-circuit design: suitable for layouts with several rooms or areas where correctly planned pipe loops are needed.
  • Consistent underfloor warmth: distribute heat across the floor with an appropriately designed water-based heating system.
  • Trade and homeowner projects: suitable for professional installation in compatible floor constructions.
  • Optional room controls: choose suitable thermostats, wiring centres and actuators where independent zone control is required.

What’s Included in Your 60m² Wet Underfloor Heating Kit?

Your kit brings together the main components for a traditional screeded underfloor heating installation. The pipework is secured to suitable floor insulation using fixing clips before the screed is laid.

Kit Contents

Component Quantity
Grundfos circulation pump and temperature mixing valve unit 1 unit
Novatherm 3-zone Dualix manifold 1 manifold
Novatherm professional grade multilayer underfloor heating pipe 300 metres
60mm pipe fixing clips 300 clips
Perimeter edge insulation 50 metres
Pipe connector cores 6
Pipe reaming tool 1

Manifold Fittings Included

The Novatherm 3-zone Dualix manifold is listed with the following fittings:

  • 2 manifold isolating valves
  • 2 temperature gauges
  • Flow meters and lockshields on the manifold ports
  • 2 drain/fill valves with blank caps
  • 2 automatic air vents
  • 2 metal mounting brackets

Thermostats and Optional Controls

Thermostats are not included in the standard kit. Customers can select thermostats and other available control accessories from the optional drop-down choices on this product page. Check the selections and order summary to confirm exactly what is included before checkout.

Before installing: Confirm your pipe spacing, insulation, circuit layout and screed specification with your installer.

Next Working Day Delivery

Applies to UK Mainland only. Order before 12:30pm Mon–Fri. Orders placed after 12:30pm Friday will arrive Tuesday. Saturday delivery is available at an extra cost.

Free delivery

UK Mainland orders over £250 (ex VAT). Larger or palletised orders outside UK Mainland may incur additional fees.

Additional Information

Deliveries are fulfilled by third-party couriers. Delivery times are estimates and we are not liable for delays. For detailed information about shipping, view our Shipping and Returns.

-Novatherm™ MLCP Multilayer pipe 
-Novatherm™ FN5C manifold complete with isolating ball valves-temperature gauges-auto air vents and drain points-adjustable flow meters
-Grundfos "A" rated 15/20 pump and blender valve
-Pipe Clips 
-Edge Insulation Roll  
-Connector cores 
-Pipe Reamer  

 

Frequently Asked Questions

Is a 60m² complete wet underfloor heating kit boiler-friendly?
The 60m2 underfloor heating kit is boiler-friendly and designed specifically for easy integration with an existing boiler. This makes installations much simpler and faster across domestic and commercial spaces.
Is 60m² intended for primary heating of a large room or several rooms?
Commonly deployed as primary heating, a 60m2 underfloor heating kit can be used over one generous space as the primary heating or split across multiple zones on the manifold, depending on heat-loss results.
What is the depth required for wet underfloor heating?
The depth required for wet underfloor heating varies between systems, for a traditional screed system the depth required for installation is around 65 to 75mm, including pipes which are typically 16mm thick and screed cover.